Soxhlet extractor BST/SWB-132
A Soxhlet extractor is a piece of laboratory apparatus. It was originally designed for the extraction of a lipid from a solid material. Typically, Soxhlet extraction is used when the desired compound has a limited solubility in a solvent, and the impurity is insoluble in that solvent. It allows for unmonitored and unmanaged operation while efficiently recycling a small amount of solvent to dissolve a larger amount of material.
Catalog number | Unit Size | Description |
---|---|---|
BST/SWB-132 | Each | Temp. Range: up to 100 deg C & Heater Rating 1000 Watts |
PRODUCT OVERVIEW
A Soxhlet extractor is a piece of laboratory apparatus. It was originally designed for the extraction of a lipid from a solid material. Typically, Soxhlet extraction is used when the desired compound has a limited solubility in a solvent, and the impurity is insoluble in that solvent. It allows for unmonitored and unmanaged operation while efficiently recycling a small amount of solvent to dissolve a larger amount of material.
SPECIFICATIONS
Water bath with two straight vertical rods and two adjustable horizontal rods and 6 clamps to hold the soxhlet extractor | |
Model No | BST/SWB-132 |
Design | Rectangular, double walled, stainless steel construction with glass wool or better insulation material. 6 holes of 75 mm diameter in row |
Outer body | Made up of thick stainless steel, duly preheated with primer and enamel painted with epoxy power coating. Provision of drain plug. Bottom shall have anti slip rubber legs for stability. |
Inner Chamber | Leak proof, easy to clean, rectangular stainless steel tank with fully rounded corned edges |
Bath size | Length: 130 cm, Width: 30 cm, Height: 25 cm |
Cover | Lid and concentric ring of stainless steel |
Temperature Range | up to 100 OC |
Temperature display | Digital |
Temperature Resolution | 10 OC or better |
Temperature Accuracy | 1 OC or better |
Heater type | Energy efficient ,Immersion type heating element |
Heater rating | 1000 watts or as per manufacturers standard practice |
Heating time | Heater rating should be sufficient to raise the temperature up to 100 OC in (maximum) 20 minutes |
Temperature Controller | Digital temperature controller |
Control Panel | On/Off switch, Heating and mains indicators lamp and temperature controller |
Power Supply | 220 ± 10 VAC,50/60 Hz ± 1, Single Phase |
Spares | Two sets of heating elements and one digital controller. Additional spares may be specified |
Safety Features | Low Fluid Alarm and Over Temperature Alarm & Cut-off |